nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2026, 06, v.43 57-62
Construction and Application of Non-Enzyme Electrochemical Sensor for Glutamate Detection Using Silver Ion as Probe
Email:
DOI:
Published:   2026-06-04
Publication Date:   2026-06-04
Mobile reading
Abstract:

Based on the strong coordination between glutamate and electrochemically active silver ion(Ag+),the oxidation peak current of Ag+ decreases and the new oxidation peak is generated, we constructed a non-enzyme electrochemical sensor for detecting glutamate.The results show that, in the range of 0.5-2 μmol·L-1,the decrease of Ag+ oxidation peak current has a good linear relationship with glutamate concentration, and the detection limit is 0.1 μmol·L-1.In the range of 8-100 μmol·L-1,the increase of new oxidation peak current has a good linear relationship with glutamate concentration, and the detection limit is 8 μmol·L-1.The sensor can be applied to the detection of sodium glutamate in monosodium glutamate with high recovery rate, which provides a new idea for rapid, simple, and accurate electrochemical detection of glutamate.

References

[1] WAGENMAKERS A J M.Protein and amino acid metabolism in human muscle[J].Advances in Experimental Medicine and Biology,1998,441:307-319.

[2] TSURUGIZAWA T,TORII K.Physiological roles of glutamate signaling in gut and brain function[J].Biological & Pharmaceutical Bulletin,2010,33(11):1796-1799.

[3] SCHOEPP D D,CONN P J.Metabotropic glutamate receptors in brain function and pathology[J].Trends in Pharmacological Sciences,1993,14(1):13-20.

[4] WALKER R,LUPIEN J R.The safety evaluation of monosodium glutamate[J].The Journal of Nutrition,2000,130(4):1049S-1052S.

[5] REINHOUD N J,BROUWER H J,van HEERWAARDEN L M,et al.Analysis of glutamate,GABA,noradrenaline,dopamine,serotonin,and metabolites using microbore UHPLC with electrochemical detection[J].ACS Chemical Neuroscience,2013,4(5):888-894.

[6] MURAT S,GÖKSEL A.Method validation and rapid determination of monosodium glutamate in various food products by HPLC-fluorescence detection and method optimization of HPLC-evaporative light scattering detection approach without derivatization[J].Journal of Chromatographic Science,2022,60(8):760-769.

[7] TUCCI S,PINTO C,GOYO J,et al.Measurement of glutamine and glutamate by capillary electrophoresis and laser induced fluorescence detection in cerebrospinal fluid of meningitis sick children[J].Clinical Biochemistry,1998,31(3):143-150.

[8] ÖZEL R E,ISPAS C,GANESANA M,et al.Glutamate oxidase biosensor based on mixed ceria and titania nanoparticles for the detection of glutamate in hypoxic environments[J].Biosensors & Bioelectronics,2014,52:397-402.

[9] HU J N,YANG S L,XUAN Y,et al.Simultaneous detection of resolved glutamate,glutamine,and γ-aminobutyric acid at 4T[J].Journal of Magnetic Resonance,2007,185(2):204-213.

[10] O′GORMAN R L,MICHELS L,EDDEN R A,et al.In vivo detection of GABA and glutamate with MEGA-PRESS:reproducibility and gender effects[J].Journal of Magnetic Resonance Imaging,2011,33(5):1262-1267.

[11] MENG L,WU P,CHEN G X,et al.Low potential detection of glutamate based on the electrocatalytic oxidation of NADH at thionine/single-walled carbon nanotubes composite modified electrode[J].Biosensors & Bioelectronics,2009,24(6):1751-1756.

[12] MAZZONE G L,NISTRI A.Electrochemical detection of endogenous glutamate release from rat spinal cord organotypic slices as a real-time method to monitor excitotoxicity[J].Journal of Neuroscience Methods,2011,197(1):128-132.

[13] LOPES P,KAEWJUA K,SHIPOVSKOV S.Glucose and glutamate detection by oxidase/heminperoxidase mimic cascades assembled on macro- and microelectrodes[J].ChemElectroChem,2024,11(5):e202300682.

[14] XU Y W,ZHU T T,NIU Y H,et al.Electrochemical detection of glutamate by metal-organic frameworks-derived Ni@NC electrocatalysts[J].Microchemical Journal,2022,175:107229.

[15] WU C T,BARKOVA D,KOMAROVA N,et al.Highly selective and sensitive detection of glutamate by an electrochemical aptasensor[J].Analytical and Bioanalytical Chemistry,2022,414(4):1609-1622.

[16] CORDEK J,WANG X W,TAN W H.Direct immobilization of glutamate dehydrogenase on optical fiber probes for ultrasensitive glutamate detection[J].Analytical Chemistry,1999,71(8):1529-1533.

[17] HU H T,LI P K,WANG Z C,et al.Glutamate oxidase-integrated biomimetic metal-organic framework hybrids as cascade nanozymes for ultrasensitive glutamate detection[J].Journal of Agricultural and Food Chemistry,2022,70(12):3785-3794.

Basic Information:

China Classification Code:O657.1;TS264.23;TP212

Citation Information:

[1]ZHAO Lingzhi,DONG Zhuo,HOU Ruxue ,et al.Construction and Application of Non-Enzyme Electrochemical Sensor for Glutamate Detection Using Silver Ion as Probe[J].Chemistry & Bioengineering,2026,43(06):57-62.

Fund Information:

西安医学院科研能力提升计划项目(2022NLTS072,2024NLTS123); 2024年陕西省大学生创新创业训练计划项目(202411840003); 陕西省科技厅项目(2022JM-094,2024JC-YBMS-640,2023-JC-QN-0629)

Published:  

2026-06-04

Publication Date:  

2026-06-04

quote

GB/T 7714-2015
MLA
APA